Skip to content

SPRAY CORK

Thermal, colored, and environmentally friendly coating for finishing facades, mortars, EIFS systems, and roofs.

Description

Thermal coating that offers a variety of options to suit the tastes of professionals and guarantee high performance, thanks to the natural properties of cork. It stands out for its breathability, which allows
surfaces to breathe and guarantees high thermal insulation, taking advantage of cork’s ability to trap and immobilize air in the cavities of its honeycomb structure. Durability, elasticity, and fire resistance complete the functional properties of a sustainable product, capable of satisfying aesthetic tastes and needs and ensuring the thermal comfort that is an integral part of well- being in the home.

FEATURES OF SPRAY CORK

Performance

75 – 86 ft2 | 7 – 8 m2 (2 layers)

0,12 in | 3 mm

Texturado

Carpeta de colores

– Contributes to insulation against cold and heat.
– Contributes to the hygrometric regulation of the environment, preventing mold and condensation dripping.
– The porosity of the product allows walls to breathe.Prevents the formation of cracks and fissures.
– Fire and high temperature resistant.
– Prevents thermal shock, dispersion, and overheating, contributing to energy savings.
– Excellent adhesion to surfaces such as metal, concrete, masonry, brick, plasterboard, fiber cement, and wood.

It can be used indoors or outdoors, on facades, EIFS systems, and roofs, whether in new construction or renovation projects.

Mix Spray Cork for at least 3 minutes or until a homogeneous mixture is achieved, then add component 2 and dye, then mix for 3 more minutes.

It is applied mechanically using a texture spraying machine. The application must be two cross coats and deliver a
minimum of 0.12 in  (3 mm). Use nozzle No. 6.

ESSAYS

RESULTS

REGULATIONS

Water vapor transmisión test

36.8 (g/m2/24hr) | 5.29 (U.S. Perms)

ASTM E96 / E96M-22

Pull-out resistance

Metal/Stell 52.0 PSI | Stucco 9.2 PSI

ASTM D4541 – 17

Surface Burning Characteristics of Building
Materials

Class ‘A’

ASTM E84-21

Fungus resistance

No fungal growths observed

ASTM G21-15

Thermal conductivity

0.050 ± 0.002 (W/m*k)

EN 12664:2001-1

Water vapor transmission properties

Permanence W 1,525E-09 (kg/m2 S Pa)
Resistivity rv 3,39 (MN s/g m)
Resistance Rv 0,008 (MN s/g)
Permeability Ᵹ 3,507E-12 (Kg/m s Pa)
Water vapor resistance factor μ 0,626

NCh 2457 of 2014

Thermal conductivity

0.041 (W/m*k)

NCh 850 of 2008

Adhesion direct traction method

Zinc 0,36 (Mpa) / Fiber cement 0,33 (Mpa)

NCh 2471 of 2000

Sound absorption coefficient

Sound reflective 0,13 < ɑ < 0,32
Range 400 Hz hasta 2000 Hz

ISO 10354-2